GAS products

DX Ammonia (NH3) Vaporizer : EVA-10DX

Ammonia Vaporizer DX

Ammonia Vaporizer DX NH3 vaporizer DX

  • Dry Electric type
  • Corrosion resist material on all Ammonia route
  • Capacity : 10 kg/h
  • Compact size
  • Solenoid Valve safety feature
  • CE certified
  • Explosion-proof : Flameproof
  • Ex d II B T2 Gb / Class-1, Division-1

 

 

Features

DESIGNED FOR AMMONIA

  • Designed exclusively for Ammonia with corrosion resistant material on all gas route

EXTREMELY SMALL SIZE

  • Single Phase power supply. Extremely SMALL DESIGN and EASY INSTALLATION!
    **1. Dimension in the picture below

CE certified

SAFETY FEATURE

  • FLAMEPROOF type Explosion Proof structure.

EASY MAINTENANCE

  • ELECTRIC (DRY) type vaporizer. Minimum maintenance required


Dimension & Flow Sheet

**1-1. Dimension

Dimention of Ammonia vaporizer DX body and components

**1-2. Flow Sheet

Specification

MODEL EVA-10DX
Vaporization Capacity kg/hr 10
Gas  NH3 (Liquefied Ammonia)
Heat Source Type Electric
Electric Heater 4.9kW
Power source Electric Heater Circuit : SinglePhase AC220V
Amparage Rating 22.3A
Control Temperature 70℃
Fuse Set Temperature 130℃
Safety Releif Valve 
Setting Pressure
psig 350
MPa 2.42
Liquid inlet bore DN15-PN40 I
Gas outlet bore DN15-PN40 I
Body Dimension(mm) Width 185
Depth 175
Height 471
Weight kg 25
Explosion-Proof Cert No. GYB18.1066X (Ex d II B T2 Gb)
Approval CE approval


<REMARKS>

    • First stage regulator must be installed right after the gas outlet of vaporizer. (If there is distance, re-condensation may occur)
    • First stage regulator outlet setting pressure must be below 0.15MPa or 22psig.
    • Install vaporizer where direct sunlight can be avoided and enough ventilation.