Catalogue Download(PDF)

Specification
Model EV-50AX5 EV-100AX5 EV-150AX5 EV-200AX5 EV-300AX5 EV-500AX5
Vaporization
Capacity
kg/hr 50 100 150 200 300 500
U.S Gal/hr * 25 50 75 100 150 250
lb/hr 110 220 330 440 660 1100
Water Bath Capacity 50 50 95 120 130 275
Heat
Exchanger
Design
Pressure
kg/cm2 18
psig 257
MPa 1.77
Liquid inlet bore Rc3/4 Rc1
Gas outlet bore Rc1 Rc1・1/4
Hydrostatic Test Pressure kg/cm2 27
psig 386
MPa 2.66
Releif Valve Setting Pressure kg/cm2 17.5
psig 250
MPa 1.72
Flame-Proof
Electric Heater
kW

8

14

21

28
(14kWx2)
42
(21kWx2)
63
(21kWx3)
Electric
Requirement
Heater
Control Circuit
200/220/380/415/440/460V,3-Phase
220V,1-Phase

Dimension
(mm)

Width 420 420 480 520 520 670
Depth 684 642 682 732 732 847
Height 857 857 1058 1098 1158 1357
Vaporizer
Control Panel Dimensions
(mm)
Width 300 450
Depth 150 250
Height 400 500
Weight kg 160 160 235 290 320 665
Ib 350 350 510 630 700 1460
Design Standard Approval Pressure Vessel/JIS B-8265
ExPlosion-ProofConstruction/NEPSI
(National Supervision and Inspection Center for Explosion Protection and Safety Instrumentation)
* When gas compostion is Propane50:Butane50 / outside temperature is 25℃
Attention
The control panel is provided together with vaporizer
Worldwide voltage available
Heater : 200 / 220 / 380 / 415 / 440 / 460V +10 / -0%)
Control circuit : 220V ±10%
Ambient temperature 0℃ ~ 40℃
Gas composition Propane : 30% / Butane : 70% ~ Propane : 100% / Butane : 0%
page top

Features
Advanced Safety Mechanism
Float valve with built-in magnet (KAGLA's Patented Technology) prevents LPG liquid carryover.
**1. See below for its operation principle.
WATER LEVEL SWITCH and SAFETY THERMOSTAT prevents over-heating of water bath
User Friendly Interface
Multi function electric control panel with digital indicator equipped
**2. See below for more details
Space Saving Compact Body
AX5 realized the minimum body size backed by long term experience of KAGLA
Easy Maintenance Structure
Top cover of AX5 is removable from its body for easy maintenance and overhaul
Varieties of Line-ups
6 different vaporization capacity models from 50kg/hr to 500kg/hr
Drainage Measure
Structure designed to minimize drainage to remain
**1. FUNCTION OF FLOAT VALVE
FLOAT VALVE is a safety function to prevent LPG liquid carryover to the consumption side
This function is controlled by the float and magnet only, but not by electricity or pilot air. Simple and reliable mechanism secures safe operation.
**2. DISPLAY ON ELECTRIC CONTROL PANEL
Control Panel   Table of Operation Status
 
Display Operation of
Vaporizer
Status
 
ON Low Water Level Warning
(Lighting)
SHUT
DOWN
Float Valve Shutoff
(overload / heater defective)
(Flashing)
Float Valve Shutoff
(thermostat defective)
 
Low Water Level Shutdown
(Lighting)
High Water Temperature Shutdown
(minimum controller defective / magnet switch defective)
(Flashing)
High Water Temperature Shutdown
(thermostat defective)
 
Float Valve Shutoff by blackout
(not a defect)
(Dot)
Electric Heater ON
 
ON Liquid Auto Changer activated
(optional)
Operation status of vaporizer can be monitored on the electric control panel from remote place